-40%

Online Earth Resistance Tester Grounding Resistance Online Detector

$ 146.66

Availability: 100 in stock
  • Line Voltage: Meausrement voltage to earth: AC below 600V
  • Condition: New
  • Restocking Fee: No
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Item must be returned within: 30 Days
  • Country/Region of Manufacture: China
  • Ground Resistance Range: 0.010Ω~2000Ω
  • Measurement Times: Above 10,000 times
  • Test Method: precision 3-wire or simple 2-wire measurement meth
  • Brand: CNYST
  • Custom Bundle: No
  • Power Supply: Standard: 12V±1VDC、400mA Max; Optinal: 24V±1VDC
  • Return shipping will be paid by: Buyer
  • All returns accepted: Returns Accepted
  • Modified Item: No
  • Data Mode: Average value
  • Dispaly mode: 4 Digits large LCD display
  • MPN: ETCR2900

    Description

    Online Earth Resistance Tester Grounding Resistance Online Detector
    Introduction
    ETCR2900 Grounding Resistance Online Detector for on-line monitoring grounding system grounding resistance, equipotential bonding resistance and grounding voltage, resistance range: 0.01Ω ~ 2000Ω, voltage range: AC 0 ~ 600V. The detector Using precision 3-wire or simple 2-wire measurement method to test the grounding resistance. Adopt average value rectification method to test grounding voltage, online detection, real-time monitoring. User can select RS232 or RS485 communication, according the protocol MODBUS to secondary development, build network, realize remote multipoint online monitoring etc.
    ETCR2900 grounding resistance on-line Detector consists of detector, monitoring software, etc., displayed by super large LCD , very clear; ensure the high accuracy,  high stability and high reliability of real-time online monitoring of grounding resistance value in various place. Suitable for transmission line tower grounding, underground mine equipment grounding , weather lightning protection grounding, petrochemical grounding ,communication base station grounding, power substation grounding , railway grounding , building warehouse grounding , electrical equipment grounding, etc.
    specification
    Online monitoring of grounding resistance, grounding voltage, equipotential bonding resistance, and low value resistance
    Power Supply
    Standard: 12V±1VDC

    400mA Max; Optinal: 24V±1VDC
    Test Method
    precision 3-wire or simple 2-wire measurement method
    Measurement Method
    Ground Resistance

    Rated current pole method, measuring current 11mA Max

    128Hz

    Ground Voltage

    Average rectification
    Data Mode
    Average value
    Dispaly mode
    4 Digits large LCD display
    Measurement Indication
    In measurement,count down indication
    LCD size
    128mm×75mm; Display area:124mmX67mm
    Tester Dimension
    190mm×117mm×54mm
    Measurement Time
    Voltage to earth: about 2 times/seconds; Grounding resistance: about 30seconds/times
    Measurement Times
    Above 10,000 times
    Line Voltage
    Meausrement voltage to earth: AC below 600V
    Tester Interface
    Plug Terminal Block: 9-pin terminal block
    Data Communication
    RS485 (optional RS232).
    Shift
    Automatic shift
    Data Storage
    400 sets, flashes display "FULL"symbol indicate that storage full
    Interval time
    Automatic monitoring interval time of setting range: 1 ~ 999 hours
    Data Access
    Data access function: display "READ" symbol
    Overfolw Indication
    Over range overflow function: display"OL" symbol
    Power Consumption
    Standby

    25mA Max
    Measurement

    400mA Max
    Alarm Indication
    audible and visual alarm
    Power Voltage
    When power voltage lower than 10V, display low power voltage symbol,and remind to replace battery
    Tester Weight
    450g
    Working Environment
    -10℃~40℃

    below 80%rh
    Store Environment
    -20℃~60℃

    below 70%rh
    Overload Protection
    In meausrment of ground resistance

    E-P

    E-C AC 280V / 3 seconds between each terminal
    Insulation Resistance
    above 10MΩ  (500V between circuit and outside shell)
    Withstand Voltage
    AC 3700V/rms(Between the circuit and the shell)
    Electromagnetic characteristics
    IEC61010-4-3

    Wireless frequency electromagnetic field≤1V/m
    Suitable Safty Standard
    IEC61010-1

    IEC1010-2-31

    IEC61557-1,5

    IEC60529(IP54)

    Pollution 2

    CAT Ⅲ 300V
    PAYMENT INFORMATION:
    1.We can accept Credit Cards,Paypal,T/T,Escrow and so on.
    2.The buyer is responsible for any tax and/or duty charged by their country.
    INTERNATIONAL SHIPPING:
    The package will be shipped by EUB DHL, FEDEX or EMS. After we shipped the parcel,we'll fill in the tracking number and inform you by e-mail.Please write the correct address and telephone number when you make orders,so the courier can contact you when they deliver the parcel to you. Thanks!
    WARRANTY INFORMATION:
    1.All the products have been checked and packed in good condition before dispatch.
    2.All the products with one year warranty.
    3.If you find any quality problems,please send it back within 3 days,and we'll send you a new one or refund you the payment after we get the returned one.
    4.Buyers have to pay for the return cost and we will pay the cost for resend
    5.All products returned should be in new conditions.