-40%

Fluke Calibration 9132-156 Portable Infrared Temperature Calibrator

$ 2757.7

Availability: 100 in stock
  • Item must be returned within: 30 Days
  • Refund will be given as: Money back or replacement (buyer's choice)
  • MPN: 9132-156
  • Condition: New
  • Brand: Fluke Calibration
  • All returns accepted: Returns Accepted
  • Return shipping will be paid by: Buyer

    Description

    Subscribe to Our Newsletter
    Fluke Calibration 9132-156 Portable Infrared (IR) Temperature Calibrator, 50 °C to 500 °C (122 °F to 932 °F), 115VAC
    Brand:
    Fluke Calibration
    Model No:
    9132-156
    Ref No:
    1658205
    Our Model No:
    9132156
    Product Overview
    Features
    Temperature range: 50 °C to 500 °C (122 °F to 932 °F)
    Accuracy: ±0.5 °C at 100 °C (±0.9 °F at 212 °F); ±0.8 °C at 500 °C (±1.4 °F at 932 °F)
    Stability: ±0.1 °C at 100 °C (±0.18 °F at 212 °F); ±0.3 °C at 500 °C (±0.54 °F at 932 °F)
    Target size: 2.25 in. (57 mm)
    Rapid heating and cooling
    Hand strap
    RS-232 interface capability
    Temperature scan rate control
    Eight set-point memory
    Adjustable readout in °C or °F
    Description
    The Fluke Calibration 9132156 Portable Infrared (IR) Calibrator, 50 °C to 500 °C (122 °F to 932 °F), 115VAC provides a stable, blackbody target for calibrating noncontact IR thermometers.
    The 9132-156 features a large, temperature controlled blackbody target with a diameter of 2.25 in. (57 mm), which offers a large field of view area for optical variations in infrared thermometers. The emissivity of the isothermal target is set at 0.95, and the target temperature can be controlled in set-point increments of 0.1°. For even higher precision, a well is located directly behind the blackbody surface for contact calibration. Using an optional calibrated PRT and readout device, target accuracy of ±0.075 °C can be achieved.
    The Fluke Calibration 9132-156 is as easy to use as "point and shoot." Simply set the desired blackbody temperature from the convenient front panel control buttons, wait a few minutes for equilibrium, and point the gun at the target. The radiated energy from the blackbody is measured by your IR thermometer. Simply compare its reading to the display on the blackbody and record the difference.
    For IR calibrations above normal ambient, the Fluke Calibration 9132-156 provides a stable blackbody target up to 500 °C (932 °F). With accuracy to ±0.5°C and stability to ±0.1 °C, this portable IR unit can certify most handheld pyrometers.
    Short heating and cooling times mean you will not have to wait long to get your work done. From room temperature to 500 °C, the 9132-156 will be stable within 30 minutes.
    Included Components
    1 - Power Cord
    1 - User Manual
    1 - Serial Cable
    1 - 9930 Interface-it Software
    Terms & Conditions
    Please note estimated delivery time above. Contact us for details or if you have a delivery requirement. We ask for your patience while striving to ensure your shipment arrives quickly and accurately.
    Domestic Shipping
    FREE Standard Shipping on items OVER and less than 30lbs to continental U.S. Add for AK, HI, or PR. Please contact us for shipping rates to any overseas US territories including: Northern Mariana Islands, Guam, Puerto Rico, U.S. Virgin Islands and American Samoa.
    PO Boxes/APOs require USPS shipping and may therefore experience longer lead times
    6.25% Sales Tax for shipping to MA
    International Shipping
    Due to international voltage requirements, please ask us prior to purchasing to confirm your product will operate correctly in your country.
    Please contact us for shipping rates to any overseas U.S. territories.
    International customers are responsible for all shipping charges, including any duties or taxes.