-40%
Fluke 5790A Automated AC Measurement Standard Calibrator Option 3 Wideband NG41
$ 6863.98
- Description
- Size Guide
Description
Fluke 5790A Automated AC Measurement Standard Calibrator NG41Option 3 Wideband
Clean Crisp Display. Passes Self tests, self diagnostics. These may be out of tolerance and require adjustments/calibrations
General Specifications
AC V Measurement
Range:
700 mV to 1000V
10 Hz to 1 MHz
Best 1Year Specification:
± 24 ppm
Wideband Measurement
Range:
700 mV to 7V
10 Hz to 30 MHz
Best 1Year Specification:
± 0.35%
Warm up Time
30 minutes
Relative Humidity
Operating:
45% to 50°C; 75% to 45°C; 95% to 30°C
Storage:
< 95% non-condensing
Altitude
Operating:
3,050 meters (10,000 feet)
Non-Operating:
12,200 meters (40,000 feet)
Temperature Performance
Operating:
0°C to 50°C
Calibration:
15°C to 35°C
Storage Temperature
-40°C to 70°C
EMI/RFI
Complies with FCC Part 15 Subpart B, Class B; VDE 0871, Class B; ESD: EIA PN-1361. Surge: ANSI C62.41-1980, Category A
Reliability
MIL-T-28800D, paragraph 3.13.3
Line Power
47 Hz to 63 Hz; +/-10% of selectable line voltages: 100V, 110V, 115V, 120V, 200V, 220V, 230V, 240V
Safety
Complies with UL 1244 and IEC348-1978 and IEC 1010 and CSA C22.2 No. 231
Interfaces
RS-232C, IEEE-488
Maximum Power
5790A: 95 VA;
with wideband: 120 VA
Calibration Documentation
CALIBRATION NOT INCLUDED
Size
Height:
17.8 cm (7 in) standard rack mount +1.5 cm (0.6 in)
Width:
43.2 cm (17 in)
Depth:
63 cm (24.8 in)
Weight
5790A: 24 kg (53 lbs.); with wideband: 24.5 kg (54 lbs
his unit is onsite, is setup and we welcome for you to come inspect this unit.
Please email if you have any questions or would like to speak with someone in person. Call Bullseye Calibration in Bloomfield, CT to discuss the machine or payment options.
We do accept Personal, Company and Bank Checks, as well as Bank Wire Transfers, and Money Orders.
SHIPPING POLICY:
We sell sensitive test and measurement equipment here on Ebay. We strive for 5-star service, so we invest a great deal of time and care to package all of our items safely for shipment. This attention to detail means it may take up to 10 days for us to prepare and ship your units out of our facility. We want to support you throughout the transaction and want you to be satisfied, so please to contact us at Bullseye Calibration in Bloomfield, CT with any questions or concerns. We do out best to ship quickly, but never at the expense of quality delivery.
RETURN POLICY:
All units are being sold "WITH A 30 DAY RIGHT OF RETURN". The auction description is written as a guide, we strongly recommend that you come view and test the units at our facility. Feel free to give us a call at Bullseye Calibration in Bloomfield, CT, and we will help answer any questions that you may have, before you purchase an item. We do not accept returns so please call with any questions that you have BEFORE you bid.