-40%

Fluke 1630-2FC Earth Ground Clamp Meter

$ 1069.19

Availability: 100 in stock
  • MPN: 1630-2 FC
  • Return shipping will be paid by: Seller
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Brand: Fluke
  • Item must be returned within: 30 Days
  • Condition: New
  • All returns accepted: Returns Accepted

    Description

    Untitled Document
    Fluke 1630-2FC Earth Ground Clamp Meter
    Model:
    1630-2 FC
    | Order No:
    1630-2FC
    Features a rugged design, this clamp meter is ideal for testing the grounding components of equipment in hard-to-reach areas, and areas that are indoors or fully paved and do not permit driving auxiliary test stakes. Additionally, it identifies ground loop resistance without disconnecting and reconnecting the earth electrode.
    Brand:
    Fluke
    Model:
    1630-2 FC
    Order No:
    1630-2FC
    Condition:
    NEW
    Description
    Fluke 1630-2FC Earth Ground Clamp Meter
    Stakeless earth ground loop and AC leakage current clamp for fast, safe indoor/outdoor earth ground resistance and AC leakage current tests
    For use to test the grounding components of equipment in hard-to-reach spaces, including areas that are indoors or fully paved and do not allow driving auxiliary test stakes. Remain on line - this earth ground clam meter identifies ground loop resistance without having to disconnect then reconnect the earth electrode from the system.
    Additionally, this clamp meter is a rugged tool that comes equipped with a heavy-duty clamp jaw which stays in alignment and calibration even in every day, on-the-job industrial environments.
    Features
    AC leakage current measurement - identify ac leakage currents without disconnecting the earth ground stake from the grounding system - ideal for system troubleshooting
    Rugged - heavy-duty clamp jaw stays in alignment and in calibration even in every day, on the job industrial environments
    Logging measurements - the earth ground clamp saves time by automatically recording data at pre-set intervals and saves up to 32,760 measurements in memory at the set logging interval
    Alarm threshold - user-defined high/low alarm limits, for rapid measurement evaluation
    Band-pass filter - selectable band-pass filter function removes unwanted noise from the ac leakage current measurement
    Fluke Connect compatible
    Stakeless measurements
    Measures earth ground loop resistances for multi-grounded systems using the dual-clamp jaw. This test technique eliminates the dangerous and time-consuming activity of disconnecting parallel grounds, as well as the process of finding suitable locations for auxiliary test stakes. You can also perform ground tests in previously difficult places: inside buildings, on power pylons or anywhere you don't have access to soil to place auxiliary test stakes.
    With this test method, a two-process measurement is made around the earth ground wire or bus bar using the specially-designed jaw of this clamp. Auxiliary test stakes are not used at all. A known voltage is induced by the source in the clamp, and the current is measured by the sensor in the clamp. The tester automatically determines the earth loop resistance for this section of the earthing system.
    Html->link('Fluke Clamp Selection Guide', DS . $filePathSetting, array('class' => 'btn btn-info', 'target' => "_blank", 'style' => '', 'escape' => false)); ?>
    Included
    Clamp Meter
    Carrying Case
    4 x AA Batteries
    Safety Information Guide
    Quick Reference Guide
    Specifications
    Electrical Specifications
    Maximum Voltage to Earth Ground
    1000 V
    Frequency Range
    40 Hz to 1 kHz
    Overload Indication
    OL
    Data Logging Capacity
    Minimum of 32,760 measurements
    Data Logging Interval
    1 second to 59 minutes and 59 seconds
    Display Reading Specification with Standard Loop Resistance
    Input (&ohm)
    0.474
    0.5
    10
    100
    Minimum
    0.417
    0.443
    9.55
    96
    Maximum
    0.531
    0.558
    10.45
    104
    Safety
    General
    IEC/EN 61010-1: Pollution Degree 2 IEC/EN 61557-1
    Measurement
    IEC/EN 61010-2-032: CAT IV 600 V / CAT III 1000 V
    Current Clamp for Leakage Current Measurements
    IEC/EN 61557-13: Class 2, ≤30 A/m
    Resistance to Earth
    IEC/EN 61557-5
    Effectiveness of the Protective Measures
    IEC/EN 61557-16
    Electromagnetic Compatibility (EMC)
    International: IEC/EN 61326-1: Portable Electromagnetic Environment
    CISPR 11: Group 1, Class B, IEC/EN 61326-2-2
    Korea (KCC): Class A equipment (Industrial broadcast and communications equipment)
    USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103
    Wireless Radio
    Frequency Range
    2412 to 2462 MHz
    Output Power
    <10 mW
    Radio Frequency Certification
    FCC ID:T68-FBLE IC:6627A-FBLE
    General Specifications
    Battery
    Type: 4 x AA Alkaline batteries (IEC/EN LR6)
    Life: More than 15 hours
    Ingress Protection
    IEC/EN 60529: IP30 with jaw closed
    LCD
    Digital reading: 9999 counts
    Refresh rate: 4 per second
    Operating Temperature
    14 to 122°F (-10 to 50°C)
    Storage Temperature
    4 to 140°F (-20 to 60°C)
    Operating Humidity
    Non condensing (<50°F) (<10 °C)
    ≤90% RH (at 50 to 86°F [10 to 30°C])
    ≤75% RH (at 86 to 104°F [30 to 40°C])
    ≤45% RH (at 104 to 122°F [40 to 50°C])
    Reference Temperature
    73 ±9°F (23 ±5°C)
    Temperature Coefficient
    0.15% x (specified accuracy)/°C (<64.4 or >82.4°F [<18 or >28°C])
    Operating Altitude
    6561' (2000 m)
    Storage Altitude
    39,370' (12,000 m)
    Dimensions
    11.1 x 4.1 x 1.9" (283 x 105 x 48 mm)
    Weight
    1.94 lbs (880 g)
    Terms & Conditions
    Item Condition:
    Unless specified otherwise all products listed are Brand New in the original factory packaging and include a full factory warranty.
    Shipping:
    We currently only ship to U.S. buyers. We ship items within one or two business days from payment. We do not process shipments on weekends and holidays. Local pick up is not available. We only ship to addresses verifiable by either PayPal or credit card issuing bank.
    Please note that we cannot alter the address once a purchase is made. In the case of PayPal payment, we will ship orders when the payment is marked “Eligible” for PayPal Seller’s protection.
    *Shipping Rates are for Continental US, Please Contact us for other US Destinations
    Payment:
    Currently all payments must be made directly though PayPal
    Sales Tax:
    We are required to charge sales tax in North Carolina
    Return Policy:
    If for any reason you are not 100% satisfied with a product you receive from us, you may return the regular stock product within 30 days from the time of receipt, for a full refund or exchange of the product you purchased (less any shipping costs). Within this time, products may be returned; freight prepaid and must be in their original packaging and in resalable condition.
    Shipping errors, missing items or damages must be reported to us immediately (damages should be accompanied by a signed bill of lading acknowledging the damage). Items returned will be inspected for damage or misuse at which time they may be subject to restocking fees, other fees or refused, prior to the issuance of any credit.