-40%
Double Clamp Digital Earth Resistance Tester Soil Resistivity Detector RS232
$ 464.64
- Description
- Size Guide
Description
Double Clamp Digital Earth Resistance Tester Soil Resistivity Detector RS232Instruction:
ETCR3200 Double Clamp Earth Resistance Tester
, through a variety of methods measuring earth resistance (range: 0.01Ω ~ 30.00 kΩ), soil resistivity (range: 0.01Ωm ~ 9000kΩm), earth voltage (range: 0.1 V ~ 100.0 V), grounding lead leakage current, AC current (range: 0.01mA ~ 600A); The tester adopts the precision 4-wire method, 3-wire method, simple 2-wire method, selection method and double-clamp method to measure grounding resistance. Large caliber current clamp design, can measure the grounding system which using large grounding down lead.It can flexibly and accurately measure arbitrary grounding resistance values of single point and mesh grounding and other complex grounding conditions. When measuring parallel grounding, it is unnecessary to disconnect any parallel grounding electrode to maximize the convenience of measurement. Import FFT (fast Fourier transform) technology, AFC (automatic frequency control) technology, ensure the measurement of high precision, high stability and reliability.
ETCR3200 Double Clamp Multi-function Grounding Resistance Tester
is composed of host machine, current clamp, monitoring software, test wires, auxiliary ground rod and communication cable. Host machine with large LCD display, white backlight, bar chart indication, clear at a glance. It can store 2000 sets of data at the same time, through the monitoring software to relize historical access and online real-time monitoring functions, dynamic display, alarm indication and auto shut down, with historical data reading, accessing, saving, reporting, printing and other functions.
Product Characteristics
1
:
2/3/4-wire method measure earth resistance,Range
:
0.00Ω
~
30.00kΩ
2
:
Selection method meausre earth resistance, Range: 0.00Ω
~
3000Ω
3
:
Doule clamp method measure earth resistance,Range:0.01~100Ω
4
:
Soil resistivity measurement, Range
:
0.00Ωm
~
9000kΩm
5
:
Earth voltage measurement,Range
:
AC 0
~
600V
6
:
AC current measurement, Range: 0.01mA
~
600A
7
:
Data storage: 2000 sets
8
:
Alarm function: audible and visual alarm
9
:
CT size: Φ68mm
Specification:
Power Supply
LR14 1.5V 6 PCS
(battery is not included during the shipping)
LCD Diamension
124mm×67mm (with backlight)
Range
Selection method meausrement: 0.01Ω
~
3000Ω
Doule clamp method measurement: 0.01~100Ω
2/3/4-wire method measurement: 0.00Ω
~
30.00kΩ
Soil resistivity: 0.00Ωm
~
9000kΩm
DC resistance: 0.00Ω
~
30.00kΩ
Earth voltage: 0.1V
~
100.0V
AC current
:
0.01mA
~
600A
Resolution
Resistance
:
0.001Ω
Soil resistivity: 0.01Ωm
Current: 0.01mA
Voltage
:
0.1V
Accuracy
±1%rdg±3dgt
Date Storage
2000 sets
Data Upload Function
With RS232 interface, software monitoring, storage data can be uploaded to computer, save and print.
Auto Power-off
After 15 minutes will auto shut down without any operation
Power Consumption
Open Backlight
:
45mA Max
Close Backlight: 25mA Max
Measurement
:
100mA Max (close backlight)
Working Environment
-10℃~40℃
;
below 80%rh
Store Environment
-20℃~60℃
;
below 70%rh
CT Size
Φ68mm
Measurement method
2/3/4-wire method measurement: rated current change-pole method, test current 20mA Max
Selection method meausrement: rated current change-pole method, test current 20mA Max
Doule clamp method measurement: non-contact mutual inductance measurement method
Soil resistivity: -pole method (Wenner method)
Earth to voltage: average rectification(between P(S)-ES interface)
AC current
:
clamp current sensor measurement
Test Frequency
128Hz/111Hz/105Hz/94Hz(AFC)
Data Mode
Average value, maximum, minimum
Line Resistance Verification
Automatic calibration
Measurement Time
Voltage to earth
:
about 0.5 second/times
AC current: about 0.5 second/times
Earth resistance, Soil resistivity
:
about 5 second/times
Measuring Times
Over 5000 times(Short-circuit test, measurementinterval time should be at least 30 seconds)
Short-circuit Test Current
AC 20mA max
Open-circuit Test Current
AC 40V max
Test Voltage Wave
Sine wave
Electrode Distance Range
Can be set 1m-100m
Line Voltage
Measur voltage to earth : below AC 600V measurement
Data Hold
“HOLD” symbol display
Data Read
“READ” symbol display
Overflow Display
“OL” symbol display
Auxiliary Ground Test
With auxiliary earth resistance test function, 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ)
Interference Test
Recognize interference signal automatically, “NOISE” symbol display when interference voltage exceed 5V
Alarm Function
Measurement value exceeds alarm setting value, will “Toot-toot-toot” alarm hint
Battery Voltage
When power voltage lower than 7.5V, display low power voltage symbol,and remind to replace battery
Overload Protection
Measurement of earth resistance: between each interfaces ofC(H)-E
、
P(S)-ES,AC 280V/3 seconds
Insulation Resistance
Over 20MΩ (between circuit and shell 500V)
Withstanding Voltage
AC 3700V/rms (Between circuit and shell)
Electromagnetic Features
IEC61010-4-3,Wireless frequency electromagnetic field≤1V/m
Suitable Safty Standard
IEC61010-1 (CAT Ⅲ 300V
、
CAT IV 150V
、
Pollution Level 2)
IEC61010-031
;
IEC61557-1 (earth resistance)
IEC61557-5 (soil resistivity)
JJG 366-2004
Weight
1653g
Tester Dimension
215mm×190mm×95mm
Packing :
Package
Outer package
Carton
Inner package
Aluminum case
Accessory
Meter
1 PCS
Current clamp
2 PCS
Aluminum case
1 PCS
Auxiliary grounding rod
(
10x150mm
)
4 PCS
Test cable yellow 10 meters
1 PCS
Test cable green 10 meters
1 PCS
Test cable red 20 meters
1 PCS
Test cable black 20 meters
1 PCS
Test cable black1.6 meters
1 PCS
Test cable red 1.6 meters
1 PCS
RS232 communication cable
1 PCS
CD
1 PCS
Manual
1 PCS
Certificate
1 PCS
Warranty Card
1 PCS